With an experience in the field of Testing and Commissioning of power system products, I look forward for an opportunity to display my skills in the field of Testing & commissioning of projects related to power systems

Professional Experience

Overseas Experience
1) Project : AUTOMETIC METER READING SYSTEM
Location : SAUDIARABIA.
Company : M/s. Auva projects and supplies co
Client : SAUDI ELECTRICITY COMPANY
Role : COMMISSIONING ENGINEER.
ADDED -4 (3PH-3W,3PH-4W)REVENUE METER TESTING
SEL-734 POWER QUALITY METER TESTING
AMR PANEL SCHEME CHECK
MODIFICATION WORK IN EXISTING PANEL
Drawings Modification for As Built.
Coordination with client& consultant
1) Project : 115/13.8KV RADWAH-2 SUBSTATION
Location : HOFUF,SAUDIARABIA.
Customer : M/s. POWER FLOW CONTRACTING CO
Client : SAUDI ELECTRICITY COMPANY
Role : COMMISSIONING ENGINEER.
Scheme checking of 132KV GIS LCC PANEL WITH SAS IMPLEMENTED SYSTEM
CT Primary & Secondary Injection Test.
Capacitor Bank & Reactor Test.
O/C&E/F Relay testing in ABB Make REF 615 .
O/V&U/V Relay testing in ABB Make REF 615 .
Auxilary Relay test (MVAX12,MVAX31,MVTP)AREVA RELAY
Auxilary Relay test (RXSF,RXMD1,SPER1C1,RXMVB2 ,RDXL-1)ABB RELAY.
AREVA P143 Relay testing
RED 670 COMMUNICATION AND BASIC KNOWLEDGE.
2) Project : 132/13.8KV SHUMISHI(8151)SUBSTATION
Location : RIYADH,SAUDIARABIA.
Customer : M/s. POWER FLOW CONTRACTING CO
Client : SAUDI ELECTRICITY COMPANY
Role : COMMISSIONING ENGINEER.
Activities:
Scheme checking of 132KV GIS LCC PANEL WITH SAS IMPLEMENTED SYSTEM
.PROTECTION PANEL SCHEME CHECK FOR 132KV PANELS
CT Primary & Secondary Injection Test.
Capacitor Bank & Reactor Test.
Surge Arrester Test.
Drawings Modification for As Built.
Coordination with client& consultant
Digital Input & Output Signal througing up to BCU & SAS
Auxilary Relay test (RXSF,RXMD1,SPER1C1,RXMVB2 ,RDXL-1)ABB REL
3) Project : POWER FACTOR CORRECTION
WESTERN REGION
Location : JEDDAH,SAUDIARABIA.
Customer : M/s. AREVA,LTD
Client : SAUDI ELECTRICITY COMPANY
Role : COMMISSIONING ENGINEER.

Activities:
Scheme checking of 13.8KV SWITCHGEAR and its PROTECTION PANEL.
Logic checks for AUTOMATIC CAPACITOR CONTROL SYSTEM.
CT,Breaker,Demand meters Test.
CT Primary & Secondary Injection Test.
Capacitor Bank & Reactor Test.
Surge Arrester Test.
DC Functional scheme Check
Drawings Modification for As Built.
Coordination with client& consultant
4

Eductation

Automatic system for using microcontrol system for industrial lighting

Hot Categories

Oil Treating & Refining Petrochemicals Ball valves Gas Processing Gate Valves Natural Gas Butterfly Valves Control Valves Fire Hydrant Globe Valves Oil & Gas Companies Exploration Transport of Hydrocarbons Production Ecological & Environmental Oil and Gas Pipeline Oil Field Services

Are you Hiring?


Reach the right candidates to fill your technical positions with Gulfoilandgas Jobs
Technical Recruitment
Our Career Center has 70,000+ resumes for employers to search
200-Engineering Consultants  News Design/construction/Engineering Graphics  News Engineering  News Engineering Services  News Production Engineering  News Project & Resource Management  News Training & Education  News
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Gulf Oil and Gas
Copyright Universal Solutions All rights reserved. - Terms of Service - Privacy Policy.