Pantheon Resources Announces Operational Update

Source: www.gulfoilandgas.com 2/21/2022, Location: North America

Pantheon Resources plc, the AIM-quoted oil and gas company with a 100% working interest in all of its oil projects spanning c. 153,000 acres adjacent and near to transportation and pipeline infrastructure on the Alaska North Slope, is pleased to provide the following update:

Operational Update - Talitha #A

The Company is pleased to announce that flow testing operations have now been completed on the Slope Fan System ("SFS"), a Brookian aged horizon, at Talitha #A. The Company perforated two separate five foot ("ft") intervals at 8160 - 8165 ft and 7855 - 7860 ft, within two distinct circa 50 ft sand bodies or 'lobes'. The two intervals were stimulated and flow tested together, producing high quality circa 35 to 38 degree API oil and averaging 45 barrels of oil per day ("BOPD") over a three day test period.

On the final day of testing, the well was flowing at a sustained rate of approximately 32 BOPD from this combined 10 ft of perforations which is highly encouraging given production wells on the Alaska North Slope are drilled horizontally, which would typically result in materially higher flow rates.

This is the first indication of producible oil in the Slope Fan on Pantheon's acreage and has significant implications for future resource and recoverable oil estimates. The two SFS lobes are in two distinct trapping systems and suggest very good reservoir properties. The Company's initial analysis suggests that the deeper of the two lobes extends below the Alkaid Deep anomaly and will be assessed in the upcoming Alkaid #2 well, planned for summer 2022. The Company has not previously provided guidance on potential resource for the SFS.

The Company is greatly encouraged by these results and will provide an estimate of resource and recoverable oil in due course, once analysis is completed and the Talitha test results are fully integrated into resource assessments and future appraisal plans.

Theta West #1 Operational Update

After casing was set, an error by a third party service company contractor working on the rig floor has delayed testing operations. A cement stage tool was improperly configured, placing cement inside the casing rather than outside casing as intended. The Company will undertake work to remove cement from within the casing, prior to performing a remedial cement squeeze job. The Company expects this work to be completed over the course of this week prior to conducting flow testing operations of the Basin Floor Fan. The issue has cost time and money, however, the Company does not believe this has compromised the reservoir potential in any way.

Jay Cheatham, CEO, said "Once again we have an excellent result from the Talitha #A testing. Similar to the Basin Floor Fan ("BFF"), we had two goals in testing the SFS: (i) to prove we had moveable oil, and (ii) to prove high quality oil. We have achieved both of these. I was on location in the flow back trailer and collected the crude personally, which is indeed light and sweet. We exceeded original expectations with the flow rates achieved from these two sand bodies. We now believe the Slope Fan extends east near the Dalton Highway giving us additional potential resource developable from gravel along the highway. The issue encountered at Theta West typify some of the frustrations in drilling and completions; thankfully we had a contingency built into our planning."

Bob Rosenthal, Technical Director, said "This is fantastic result particularly given we only perforated two, five foot intervals in a vertical well. This test confirms light oil in the SFS which is not accounted for in any of our resource assessments. As we do further work, we expect an upgrade to our resource numbers for these results. Encouragingly, our testing to date suggests that we could be in the sweet spot for finding light oil on the North Slope. So far, we have tested light oil in four hydrocarbon accumulations: (i) the Alkaid (deep) anomaly, (ii) the Lower BFF, (iii) the Slope Fan System upper lobe, and (iv) the Lower Slope lower lobe."


Australia >>  8/11/2022 - • 2.6 million standard cubic feet (mmscf) per day sustained initial flow rate achieved over the first 91 hours of flow testing with minimal decline in...
United Kingdom >>  8/11/2022 - Hurricane Energy plc, the UK based oil and gas company, provides an update on Lancaster field operations and net free cash balances as of 31 July 2022...

Egypt >>  8/4/2022 - An update on the drilling of the Al Jahraa-14 development well (AJ-14) in the Abu Sennan licence, onshore Egypt, is being released by United Oil & Gas...
Nigeria >>  7/29/2022 - San Leon, the independent oil and gas production, development and exploration company focused on Nigeria, notes the announcement made by Decklar Resou...

Ivory Coast (Cote D'Ivoire) >>  7/28/2022 - Eni has successfully drilled the Baleine East 1X well, the first exploration well in block CI-802 and second discovery on the Baleine structure, offsh...
Algeria >>  7/25/2022 - Eni and SONATRACH announce a further discovery in Sif Fatima II concession, located in the Berkine North Basin in the Algerian desert. The Rhourde Oul...




Gulf Oil and Gas
Copyright © 2021 Universal Solutions All rights reserved. - Terms of Service - Privacy Policy.