Standard: API Spec 14A-2000
Application: Verification test and function test on SCSSV (Surface controlled Subsurface Safety Valve) as per API 14A, including: gas/fluid flow test, leakage test and temp control test, etc.
Technical Data:
Gas Flow Test:
- Test medium: compressed air
- Test pressure: 2000-2500psi
- Pressure precision: 0.5%
- Pressure control precision: 1%
- Flowrate: 10-600,000M3/d
Fluid Flow Test:
- Test medium: water and mud
- Water flow: 79-2,800M3/d
- Mud flow: 79-935M3/d
- Test pressure: 2000-2500psi
- Pressure precision: 0.5%
- Pressure control precision: 1%
Leakage Test:
- Test medium: Compressed Air, Nitrogen, Methane, Water and Mud.
- Test pressure: Compressed air: 0-140Mpa, Nitrogen: 0-140Mpa, Methane: 2.8Mpa and water: 200Mpa.
- Pressure precision: 0.5%, Pressure control precision: 1%, Fluid leakage measuring range: 0-10mL/min and Gas leakage measuring range: 0-140L/min
Temp Control Test:
Test medium: Nitrogen
Test temp: 38±3 82±3
Test pressure: 0 - 140Mpa
Features:
- Strictly conform with the standard of API Spec 14A, Testing process fully controlled by PC, all settings and operations can be executed on the centralized control panel, All tests can be achieved via control panel on test site and all-round monitoring of test process, and video archive is available.