Fuel Consumption Flow Meters
Gas meters
Reference N.F 4501/2010
Date 10/19/2010
Location Middle East
Scope
1- Supply of # 4 electronic flow meters to measure the consumption as the following specifications:
Product: (HN & LN)
Pipe size: 1.5" vertical installation Flow direction towards up
F.R.R.: (0.1 to 1.5) m/hr
Op.Temp: (30 to 85) C
Op. pressure: (9 10) bar
Differential pressure: 0.5 bar
Sp. Gr.: (0.65 to 0.75)
Used for units (1, 2, 3) Fueling (liquid phase) to the furnaces with strainer and air release.

2- Supply of # 4 electronic flow meters to measure the consumption as the following specifications:
Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2s)
Pipe size: 4" horizontal installation
F.R.R.: (100 to 500) Nm/hr
Op.Temp: (30 to 65) C
Op. pressure: (0.1 to 2.5) bar
Differential pressure: 0.05 bar
Density: 3.4 Kg/m
Used for units (1, 2, 3) Fuel (gas phase) to the flair

3- Supply of # 4 electronic flow meters to measure the consumption as the following specifications:
Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2S)
Pipe size: 4" horizontal installation
F.R.R.: (30 to 350) Nm/hr
Op.Temp: (30 to 65) C
Op. pressure: (0.1 to 2.5) bar
Differential pressure: 0.05 bar
Density: 3.4 Kg/m
Used for units (1, 2, 3) Fuel (gas phase) to the furnaces
These flow meters should be blind head type (equipped with a separate remote
Display) mounted on the wall

4- Supply of # 3 electronic flow meters to measure the consumption as the following specifications:
Product: Gas Oil
Pipe size: 1.5 "horizontal installation
F.R.R.: (2 to 20) m/hr
Op.Temp: (10 to 65) C
Op. pressure: (2 to 3) bar
Differential pressure: 0.3 bar
For units (1, 3) Fuel (liquid phase to the Boiler & Generator.
Water & Sediment V%: 0.05
ASH Max% 0.01 weight
These flow meters should be blind head type (equipped with a separate display) mounted on the wall (remote) with strainer and air release

5- Supply of # 1 electronic flow meters to measure the consumption as the following specifications:
Product: Gas Oil
Pipe size: 1.5" horizontal installation
F.R.R.: (1 to 10) m/hr
Op.Temp: (10 to 65) C
Water & Sediment V%: 0.05
ASH Max% 0.01 weight
Op. pressure: (2 to 3) bar
Differential pressure: 0.3 bar
For unit (2) Fuel (liquid phase) to the Boiler
These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall with strainer and air release

6- Supply of # 2 electronic flow meters to measure the consumption as the following specifications:
Product: Gas Oil
F.R.R.: (1 to 10) m/hr
Op.Temp: (10 to 65) C
Water & Sediment V%: 0.05
ASH Max% 0.01 weight
p. Pressure: (2 to 3) bar
Differential pressure: 0.3 bar
For unit (2) Fuel (liquid) to the Generator with strainer and air release

Bidding Information

Bid Bond 1% of submitted prices
Documents Price ID 100,000
Gas meters
Related Prooducts: Gas meters Analyzers, Gas Calibration Equipment Calibrators, Electronic, Pneumatic Concentration Conductivity Meters Density Detector, Gas Dissolved Oxygen meters Drilling Instruments Float Switch Gas meters General Indicators and Recorders Leak Locators Level meters Liquid Measurement Load cells Monitoring & Control Mud Control Mud Logging pH and REDOX Pressure gauges/ Transmitters Radiation Detection SCADA Systems Temperature gauges/ Transmitters Thermocouples Thermowells Transducers Transmitters Transmitters, Pressure Turbidity Meters Viscosity Weather Station Weighing Equipment
Related Tenders: Analyzers, Gas Calibration Equipment Calibrators, Electronic, Pneumatic Conductivity Meters Density Detector, Gas Dissolved Oxygen meters Drilling Instruments Gas meters General Indicators and Recorders Leak Locators Level meters Liquid Measurement Monitoring & Control Mud Logging Pressure gauges/ Transmitters SCADA Systems Temperature gauges/ Transmitters Thermocouples Thermowells Transmitters Transmitters, Pressure Viscosity Weather Station

Related Articles

For Buyers
For Suppliers
Gulf Oil and Gas
Copyright 2021 Universal Solutions All rights reserved. - Terms of Service - Privacy Policy.